{"id":40923,"date":"2024-10-25T10:20:24","date_gmt":"2024-10-25T08:20:24","guid":{"rendered":"http:\/\/batimedianews.com\/live\/?p=40923"},"modified":"2025-04-08T20:10:02","modified_gmt":"2025-04-08T18:10:02","slug":"utherm-wall-k-gyp-h-isolation-par-linterieur-des-murs-et-finition-tout-en-un","status":"publish","type":"post","link":"http:\/\/batimedianews.com\/live\/index.php\/2024\/10\/25\/utherm-wall-k-gyp-h-isolation-par-linterieur-des-murs-et-finition-tout-en-un\/","title":{"rendered":"UTHERM Wall K Gyp H &#8211; Isolation par l\u2019int\u00e9rieur des murs et finition tout-en-un"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"1482\" height=\"606\" src=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-398.png\" alt=\"\" class=\"wp-image-40924\" srcset=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-398.png 1482w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-398-768x314.png 768w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-398-432x177.png 432w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-398-396x162.png 396w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-398-1120x458.png 1120w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-398-660x270.png 660w\" sizes=\"(max-width: 600px) 91vw, (max-width: 900px) 600px, (max-width: 1060px) 50vw, (max-width: 1200px) 520px, (max-width: 1400px) 43vw, 600px\" \/><\/figure>\n\n\n\n<p><strong>Dans l\u2019habitat, apr\u00e8s le toit qui repr\u00e9sente 30% des d\u00e9perditions thermiques, les murs sont responsables de 15 \u00e0 25% d\u2019\u00e9nergie gaspill\u00e9e s\u2019ils ne sont pas ou mal isol\u00e9s. Pour r\u00e9aliser efficacement et rapidement l\u2019isolation et la finition des murs int\u00e9rieurs, Unilin Insulation lance Utherm Wall K Gyp H, un nouveau complexe 2 en 1 associant isolant en mousse de polyur\u00e9thane et plaque de pl\u00e2tre BA13 H1.&nbsp;<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 27%\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" width=\"372\" height=\"694\" src=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-399.png\" alt=\"\" class=\"wp-image-40925 size-full\" srcset=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-399.png 372w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-399-768x1432.png 768w\" sizes=\"(max-width: 600px) 91vw, (max-width: 900px) 600px, (max-width: 1060px) 50vw, (max-width: 1200px) 520px, (max-width: 1400px) 43vw, 600px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Sp\u00e9cialement d\u00e9velopp\u00e9 pour isoler par l\u2019int\u00e9rieur des murs en doublage coll\u00e9 selon le DTU 25.42, <strong>Utherm Wall K Gyp H<\/strong> est compos\u00e9 d\u2019une plaque de mousse rigide en polyur\u00e9thane contrecoll\u00e9e sur une de ses faces \u00e0 une plaque de pl\u00e2tre BA13 hydrofuge de 12,5 mm.&nbsp;<\/p>\n\n\n\n<p>Tout-en-un, le syst\u00e8me <strong>Utherm Wall K Gyp H<\/strong> assure l\u2019isolation et la finition des murs, en neuf comme en r\u00e9novation.&nbsp;<\/p>\n\n\n\n<p>Propos\u00e9 au format standard de 2700 x 1200 mm et en trois \u00e9paisseurs (92,5 &#8211; 112,5 et 132,5 mm), <strong>Utherm Wall K Gyp H<\/strong> est un isolant qui pr\u00e9sente des performances thermiques \u00e9lev\u00e9es : son faible coefficient lambda (\u03bb = 0,022) permet d\u2019obtenir une r\u00e9sistance thermique de 3,75 \u00e0 5,60 m<sup>2<\/sup>.K\/W, en fonction de l\u2019\u00e9paisseur choisie.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:36% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" width=\"1636\" height=\"1000\" src=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-400.png\" alt=\"\" class=\"wp-image-40926 size-full\" srcset=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-400.png 1636w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-400-768x469.png 768w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-400-432x264.png 432w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-400-396x242.png 396w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-400-1120x685.png 1120w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-400-660x403.png 660w\" sizes=\"(max-width: 600px) 91vw, (max-width: 900px) 600px, (max-width: 1060px) 50vw, (max-width: 1200px) 520px, (max-width: 1400px) 43vw, 600px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Faciles \u00e0 mettre en oeuvre, les plaques isolantes <strong>Utherm Wall K Gyp H <\/strong>d\u2019<strong>Unilin Insulation<\/strong> s\u2019assemblent ais\u00e9ment et se fixent notamment par collage sur un mur.&nbsp;<\/p>\n\n\n\n<p>Les plaques peuvent \u00e9galement \u00eatre viss\u00e9es, dans les limites du DTU 25.42, \u00e0 des ossatures et associ\u00e9es \u00e0 de la laine min\u00e9rale semi-rigide, plac\u00e9e entre les ossatures, afin d\u2019am\u00e9liorer encore le confort acoustique et\/ou thermique des occupants.&nbsp;<\/p>\n\n\n\n<p>Les plaques <strong>Utherm Wall K Gyp H <\/strong>sont utilis\u00e9es pour isoler un local chauff\u00e9 d\u2019un local non chauff\u00e9 ou de l\u2019ext\u00e9rieur.&nbsp;<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 32%\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" width=\"1024\" height=\"1024\" src=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-401-1024x1024.png\" alt=\"\" class=\"wp-image-40927 size-full\" srcset=\"http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-401-1024x1024.png 1024w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-401-600x600.png 600w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-401-300x300.png 300w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-401-1536x1536.png 1536w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-401-2048x2048.png 2048w, http:\/\/batimedianews.com\/live\/wp-content\/uploads\/2024\/10\/image-401-10x10.png 10w\" sizes=\"(max-width: 600px) 91vw, (max-width: 900px) 600px, (max-width: 1060px) 50vw, (max-width: 1200px) 520px, (max-width: 1400px) 43vw, 600px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Class\u00e9 A+ en ce qui concerne les \u00e9missions dans l\u2019air int\u00e9rieur, b\u00e9n\u00e9ficiant du marquage CE, d\u2019une DOP et certifi\u00e9 ACERMI, <strong>Utherm Wall K Gyp H <\/strong>est \u00e9ligible aux aides financi\u00e8res \u00e0 la r\u00e9novation selon le niveau requis et r\u00e9pond aux exigences de la RE 2020 en construction neuve.&nbsp;<\/p>\n\n\n\n<p>Avec <strong>Utherm Wall K Gyp H, Unilin Insulation<\/strong> r\u00e9pond aux attentes des constructeurs de maisons individuelles en leur apportant un syst\u00e8me pr\u00eat \u00e0 poser, sans d\u00e9perditions thermiques.&nbsp;<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dans l\u2019habitat, apr\u00e8s le toit qui repr\u00e9sente 30% des d\u00e9perditions thermiques, les murs sont responsables de 15 \u00e0 25% d\u2019\u00e9nergie gaspill\u00e9e s\u2019ils ne sont pas ou mal isol\u00e9s. Pour r\u00e9aliser efficacement et rapidement l\u2019isolation et la finition des murs int\u00e9rieurs, Unilin Insulation lance Utherm Wall K Gyp H, un nouveau complexe 2 en 1 associant [&hellip;]<\/p>\n","protected":false},"author":41,"featured_media":40928,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[4,868,80,777],"tags":[],"_links":{"self":[{"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/posts\/40923"}],"collection":[{"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/users\/41"}],"replies":[{"embeddable":true,"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/comments?post=40923"}],"version-history":[{"count":2,"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/posts\/40923\/revisions"}],"predecessor-version":[{"id":40938,"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/posts\/40923\/revisions\/40938"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/media\/40928"}],"wp:attachment":[{"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/media?parent=40923"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/categories?post=40923"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/batimedianews.com\/live\/index.php\/wp-json\/wp\/v2\/tags?post=40923"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}